Vicat Softening Temperature |
 |
ASTM D1525
ISO 306
A2LA Accredited
click on pictures for a larger view
|
 |
Scope:
The Vicat softening temperature is the temperature at which a flat-ended needle penetrates the specimen to the depth of 1 mm under a specific load. The temperature reflects the point of softening to be expected when a material is used in an elevated temperature application.
Test Procedure:
A test specimen is placed in the testing apparatus so that the penetrating needle rests on its surface at least 1 mm from the edge. A load of 10N or 50N is applied to the specimen. The specimen is then lowered into an oil bath at 23 degrees C. The bath is raised at a rate of 50° or 120° C per hour until the needle penetrates 1 mm.
Specimen Size:
The test specimen must be between 3 and 6.5 mm thick and at least 10 mm in width and length. No more than three layers may be stacked to achieve minimum thickness.
Data:
The Vicat softening test determines the temperature at which the needle penetrates 1 mm.
Equipment used at Plastics Technology Laboratories, Inc.:
Atlas HDV2 DTUL/ Vicat tester.
|
|

Intertek PTL Overview |
|
|